ALEX BLYTHE · 2026-09-21 · RETAINED-EVIDENCE CORRECTION AUDIT

HX-CFD-QUAL-01 V2.1 acceptance-path correction

A bounded audit of the evaluator and retained fine-grid continuation evidence. No CFD was rerun, and the historical qualification disposition was not rescored.

Current disposition

DIAGNOSTIC_CORRECTION_COMPLETE

HX-CFD-QUAL-01 remains FAILED_NUMERICAL_GATES. Mesh independence remains NOT_EVALUATED. HX-03 and HX-04 remain blocked.

What was corrected

  • The field-stationarity predicate now requires non-empty finite normalized RMS updates at or below the frozen 0.001 limit. The prior predicate checked only that values were greater than zero.
  • The continuation analyzer now reports the retained surfaceFieldValue rows through 1000 s instead of claiming that post-800 s monitor rows were absent.

Retained continuation evidence

QuantityResultInterpretation
Shell outlet temperature span, 800–1000 s0.002804 KSupporting evidence; not a qualification pass
Tube outlet temperature span, 800–1000 s0.001040 KSupporting evidence; not a qualification pass
Tube U global normalized RMS, 900–1000 s0.000762Below the declared global stationarity limit for this interval
Tube U declared local normalized RMS0.000791Not a valid localized manifold metric; the mask covers 98.646% of tube cells

Evidence limits that remain

  • The declared x ≤ 0.05 m mask contains 391,955 of 397,335 tube cells. It does not isolate the inlet manifold.
  • Field comparisons are positional/truncated rather than proven by explicit cell identity or topology correspondence.
  • Endpoint p/p_rgh values include negatives while the declared property-pressure interval begins at 0 Pa. Pressure-reference semantics remain NOT_ESTABLISHED.
  • Full hot/cold energy-storage closure and integrated conductive interface heat-rate evidence remain unresolved in this branch.

Artifact integrity

Continuation source immutability remains true. The corrected continuation manifest is parseable and verifies 219 artifacts with 0 missing and 0 mismatches.

Download Markdown report · Download structured results · Verification

Next authorized step

Repair the local-region definition, explicit field correspondence, pressure-reference interpretation, and complete energy/interface evidence in a versioned acceptance contract. Then decide whether a fresh three-grid campaign is warranted. No qualification or mesh comparison is authorized by this audit.

Prepared by Alex Blythe · Report date: . This is an evidence correction, not a design release or experimental validation.