AERO / PROFILE DECISION - 2026-09-19

Two-fluid CHT profile freeze decision

Alex Blythe - retained evidence only; no new CFD was run.

FINAL DISPOSITION

PROFILE_FROZEN_CASE_THRESHOLDS_PREDECLARED

The evidence categories and accounting semantics are frozen. Numerical limits remain declared by each qualification case; no universal outer-update threshold was invented.

What the profile requires

  • Run completion and linear-solver health.
  • Separate flow and thermal nonlinear settling from long-timescale field stationarity.
  • Case-declared monitor stability, hot/cold mass conservation, energy closure, and interface consistency.
  • Property validity, conditional local-field stationarity, and V2 mesh independence.

Energy accounting must include solid storage: Q_hot_signed + Q_cold_signed + dE_solid/dt ≈ 0.

Evidence basis

EvidenceDisposition
Pair 2 positive truthEstablished at 240 s
Pair 2 negativeIndependently unsettled; retained unchanged
Positive repeatabilityExact match
Analytical / energy / interface evidencePass at T2
Universal PIMPLE thresholdNot supported
Historical HX-CFD mesh resultFail: 1.303% > 1.000%

What happens next

HX-CFD-QUAL-01 is eligible only for a future clean V2 requalification. The proposed contract requires coarse, medium, and fine cases to reach equivalent profile-defined settled states before mesh comparison, including local inlet-manifold stationarity where it drives engineering quantities.

HX-CFD remains FAILED_NUMERICAL_GATES and withheld. HX-03 remains FROZEN_AND_BLOCKED. HX-04 Stage B remains blocked because its high-pressure cryogenic property/solver class was not established by this evidence.